T1 - Acta Plane—A New Reference for Virtual Orientation of Cone Beam Computed Tomography Scans
T2 - A Pilot Study
AU - Sanders-Mello, Fernanda
AU - de Menezes, Luciane Macedo
AU - Puetter, Ursula Tavares
AU - Azeredo, Fabiane
AU - Griekspoor, Tina Cornelia Antonieke
AU - de Windt, Sergio
AU - Livas, Christos
AU - Jonkman, Ronald E.G.
AU - Rozema, Frederik Reinder
AU - Koolstra, Jan Harm
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2024/1/1
Y1 - 2024/1/1
N2 - Introduction: Cone Beam Computed Tomography (CBCT) scans should be digitally oriented using a reference plane before being evaluated for patient growth and treatment outcome. Current orientation planes are usually dependent on the Porion points. Using more reliable landmarks than the Porion, we introduce the Acta plane and investigate its reliability as an alternative reference plane for cases in which the Porion point is inaccessible. Methods: To test its reliability, a dental student and an orthodontist located sixteen skeletal and dental landmarks in sixteen CBCT scans before and after reorientation. Also, four measurements were calculated based on these landmarks’ coordinates. The reorientation of these CBCT scans with the Acta plane was performed by another dental student. The Intraclass Correlation Coefficient (ICC) was calculated before and after orientation, as well as the intra and inter-examiner. The data were tested for significance through the Shapiro–Wilk test with a threshold set at 0.05. Through the ICC variation of the points’ coordinates, this article also evaluated the reliability of this plane with the t-paired and exact-sign tests. Results: The identification of landmarks was more reliable in the reoriented CBCT images than in the original images, with a significant increase of 0.012 in the median of the ICC. Linear and angular measures showed no significant differences between groups. Conclusion: This plane is a reliable alternative for the orientation of CBCT images. The design of the Acta plane might allow the use of a smaller field of view and, consequently, a reduction in the radiation dose.
AB - Introduction: Cone Beam Computed Tomography (CBCT) scans should be digitally oriented using a reference plane before being evaluated for patient growth and treatment outcome. Current orientation planes are usually dependent on the Porion points. Using more reliable landmarks than the Porion, we introduce the Acta plane and investigate its reliability as an alternative reference plane for cases in which the Porion point is inaccessible. Methods: To test its reliability, a dental student and an orthodontist located sixteen skeletal and dental landmarks in sixteen CBCT scans before and after reorientation. Also, four measurements were calculated based on these landmarks’ coordinates. The reorientation of these CBCT scans with the Acta plane was performed by another dental student. The Intraclass Correlation Coefficient (ICC) was calculated before and after orientation, as well as the intra and inter-examiner. The data were tested for significance through the Shapiro–Wilk test with a threshold set at 0.05. Through the ICC variation of the points’ coordinates, this article also evaluated the reliability of this plane with the t-paired and exact-sign tests. Results: The identification of landmarks was more reliable in the reoriented CBCT images than in the original images, with a significant increase of 0.012 in the median of the ICC. Linear and angular measures showed no significant differences between groups. Conclusion: This plane is a reliable alternative for the orientation of CBCT images. The design of the Acta plane might allow the use of a smaller field of view and, consequently, a reduction in the radiation dose.
KW - cone-beam computed tomography
KW - diagnostic imaging
KW - observer variation
KW - patient positioning
KW - reproducibility of results
KW - spatial orientation
KW - three-dimensional imaging
UR - http://www.scopus.com/inward/record.url?scp=85192232661&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85192232661&partnerID=8YFLogxK
U2 - 10.3390/app14010347
DO - 10.3390/app14010347
M3 - Article
AN - SCOPUS:85192232661
SN - 2076-3417
VL - 14
SP - 1
EP - 13
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 1
M1 - 347
ER -