Abstract
A novel method for the identification of glutathione/electrophile adducts that are inhibiting glutathione-S-transferase (GST) activity was developed and applied for the analysis of the mycotoxin patulin. The method is based on high-performance liquid chromatography (HPLC) coupled to a continuous-flow enzyme reactor serving as biochemical detector (BCD) in parallel to electrospray mass spectrometric detection (ESI-MS). This HPLC-BCD technique combines a separation step and the detection of the inhibition and is therefore ideally suited for the analysis of the activity of single patulin/glutathione adducts within a complex mixture of adducts. Two out of at least 15 detected patulin-glutathione adducts showed strong GST inhibition. In ESI-MS, the inhibitory active adducts were characterized by [M + H]
Original language | English |
---|---|
Pages (from-to) | 1361-73 |
Journal | Analytical and Bioanalytical Chemistry |
Volume | 394 |
Issue number | 5 |
DOIs | |