Abstract
An analytical method combining both a simple, fast and efficient solvent microextraction and a sensitive and selective monitoring mode, based on ion isolation ion-trap mass spectrometry (MS), was developed for analysis of perfluorinated compounds (PFCs) in biota. The method involved the vortex-shaking of 0.2g of tissue sample and 800μL of tetrahydrofuran (THF):water (75:25, v/v) for 7min, subsequent centrifugation for 13min and direct quantitation of PFCs in the extract against solvent-based calibration curves. Selection of solvent composition was based on Hildebrand solubility parameters and their components (i.e. dispersion, dipole-dipole and hydrogen bonding forces). Recoveries in samples for PFCs with hydrocarbon chain lengths between C
| Original language | English |
|---|---|
| Pages (from-to) | 3774-3782 |
| Journal | Journal of Chromatography A |
| Volume | 1217 |
| Issue number | 24 |
| DOIs | |
| Publication status | Published - 2010 |
Bibliographical note
J 1UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Fingerprint
Dive into the research topics of 'Analysis of perfluorinated compounds in biota by microextraction with tetrahydrofuran and liquid chromatography/ion isolation-based ion-trap mass spectrometry'. Together they form a unique fingerprint.Cite this