Abstract
Purpose: Autotransplantation of premolars is a good treatment option for young patients who have missing teeth. This study evaluated the use of a preoperatively 3-dimensional (3D)-printed replica of the donor tooth that functions as a surgical guide during autotransplantation.
Materials and Methods: Five consecutive procedures were prospectively observed. Transplantations of maxillary premolars with optimal root development were included in this study. A 3D-printed replica of the donor tooth was used to prepare a precisely fitting new alveolus at the recipient site before extracting the donor tooth. Procedure time, extra-alveolar time, and number of attempts needed to achieve a good fit of the donor tooth in the new alveolus were recorded.
Results: For each transplantation procedure, the surgical time was shorter than 30 minutes. An immediate good fit of the donor tooth in the new alveolus was achieved with an extra-alveolar time shorter than 1 minute for all transplantations.
Conclusion: These results show that the extra-alveolar time is very short when the surgical guide is used; therefore, the chance of iatrogenic damage to the donor tooth is minimized. The use of a replica of the donor tooth makes the autotransplantation procedure easier for the surgeon and facilitates optimal placement of the transplant.
Materials and Methods: Five consecutive procedures were prospectively observed. Transplantations of maxillary premolars with optimal root development were included in this study. A 3D-printed replica of the donor tooth was used to prepare a precisely fitting new alveolus at the recipient site before extracting the donor tooth. Procedure time, extra-alveolar time, and number of attempts needed to achieve a good fit of the donor tooth in the new alveolus were recorded.
Results: For each transplantation procedure, the surgical time was shorter than 30 minutes. An immediate good fit of the donor tooth in the new alveolus was achieved with an extra-alveolar time shorter than 1 minute for all transplantations.
Conclusion: These results show that the extra-alveolar time is very short when the surgical guide is used; therefore, the chance of iatrogenic damage to the donor tooth is minimized. The use of a replica of the donor tooth makes the autotransplantation procedure easier for the surgeon and facilitates optimal placement of the transplant.
Original language | English |
---|---|
Pages (from-to) | 1114-1119 |
Journal | Journal of Oral and Maxillofacial Surgery |
Volume | 74 |
Issue number | 6 |
DOIs | |
Publication status | Published - 2016 |