Development of a luminescent mutagenicity test for high-throughput screening of aquatic samples

Nick Zwart, Marja H. Lamoree, Corine J. Houtman, Jacob de Boer, Jeroen Kool, Timo Hamers

Research output: Scientific - peer-reviewArticle

Abstract

The Salmonella reversion based Ames test is the most widely used method for mutagenicity testing. For rapid toxicity assessment of e.g. water samples and for effect-directed analysis, however, the Ames test suffers from lack of throughput and is regarded as a laborious, time consuming method. To achieve faster analysis, with increased throughput, a (downscaled) luminescent derivative of the Ames Salmonella/microsome fluctuation test has been developed through expression of the Photorhabdus luminescens luciferase in the Salmonella TA98 and TA100 strains. The applicability of this test is demonstrated by analysis of environmentally relevant compounds, a suspended particulate matter extract and an industrial effluent sample. Use of the luminescent reporter reduced the required detection time from 48 to 28 h with a specificity of 84% for responses reported in the literature to a set of 14 mutagens as compared to 72% in the unmodified fluctuation test. Testing of the same compounds in a downscaled luminescent format resulted in an 88% similarity with the response found in the regular luminescent format. The increase in throughput, faster analysis and potential for real-time bacterial quantification that luminescence provides, allows future application in the high-throughput screening of large numbers of samples or sample fractions, as required in effect-directed analysis in order to accelerate the identification of (novel) mutagens.

LanguageEnglish
Pages350-360
Number of pages11
JournalToxicology in Vitro
Volume46
DOIs
StatePublished - 6 Sep 2017

Cite this

@article{4114cedd1b8b4107b005bd98bb6cf3ab,
title = "Development of a luminescent mutagenicity test for high-throughput screening of aquatic samples",
abstract = "The Salmonella reversion based Ames test is the most widely used method for mutagenicity testing. For rapid toxicity assessment of e.g. water samples and for effect-directed analysis, however, the Ames test suffers from lack of throughput and is regarded as a laborious, time consuming method. To achieve faster analysis, with increased throughput, a (downscaled) luminescent derivative of the Ames Salmonella/microsome fluctuation test has been developed through expression of the Photorhabdus luminescens luciferase in the Salmonella TA98 and TA100 strains. The applicability of this test is demonstrated by analysis of environmentally relevant compounds, a suspended particulate matter extract and an industrial effluent sample. Use of the luminescent reporter reduced the required detection time from 48 to 28 h with a specificity of 84% for responses reported in the literature to a set of 14 mutagens as compared to 72% in the unmodified fluctuation test. Testing of the same compounds in a downscaled luminescent format resulted in an 88% similarity with the response found in the regular luminescent format. The increase in throughput, faster analysis and potential for real-time bacterial quantification that luminescence provides, allows future application in the high-throughput screening of large numbers of samples or sample fractions, as required in effect-directed analysis in order to accelerate the identification of (novel) mutagens.",
keywords = "Ames test, Bacterial luciferase, Bioassay, Downscaling, Mutagenicity testing, Salmonella",
author = "Nick Zwart and Lamoree, {Marja H.} and Houtman, {Corine J.} and {de Boer}, Jacob and Jeroen Kool and Timo Hamers",
year = "2017",
month = "9",
doi = "10.1016/j.tiv.2017.09.005",
volume = "46",
pages = "350--360",
journal = "Toxicology in Vitro",
issn = "0887-2333",
publisher = "Elsevier Limited",

}

Development of a luminescent mutagenicity test for high-throughput screening of aquatic samples. / Zwart, Nick; Lamoree, Marja H.; Houtman, Corine J.; de Boer, Jacob; Kool, Jeroen; Hamers, Timo.

In: Toxicology in Vitro, Vol. 46, 06.09.2017, p. 350-360.

Research output: Scientific - peer-reviewArticle

TY - JOUR

T1 - Development of a luminescent mutagenicity test for high-throughput screening of aquatic samples

AU - Zwart,Nick

AU - Lamoree,Marja H.

AU - Houtman,Corine J.

AU - de Boer,Jacob

AU - Kool,Jeroen

AU - Hamers,Timo

PY - 2017/9/6

Y1 - 2017/9/6

N2 - The Salmonella reversion based Ames test is the most widely used method for mutagenicity testing. For rapid toxicity assessment of e.g. water samples and for effect-directed analysis, however, the Ames test suffers from lack of throughput and is regarded as a laborious, time consuming method. To achieve faster analysis, with increased throughput, a (downscaled) luminescent derivative of the Ames Salmonella/microsome fluctuation test has been developed through expression of the Photorhabdus luminescens luciferase in the Salmonella TA98 and TA100 strains. The applicability of this test is demonstrated by analysis of environmentally relevant compounds, a suspended particulate matter extract and an industrial effluent sample. Use of the luminescent reporter reduced the required detection time from 48 to 28 h with a specificity of 84% for responses reported in the literature to a set of 14 mutagens as compared to 72% in the unmodified fluctuation test. Testing of the same compounds in a downscaled luminescent format resulted in an 88% similarity with the response found in the regular luminescent format. The increase in throughput, faster analysis and potential for real-time bacterial quantification that luminescence provides, allows future application in the high-throughput screening of large numbers of samples or sample fractions, as required in effect-directed analysis in order to accelerate the identification of (novel) mutagens.

AB - The Salmonella reversion based Ames test is the most widely used method for mutagenicity testing. For rapid toxicity assessment of e.g. water samples and for effect-directed analysis, however, the Ames test suffers from lack of throughput and is regarded as a laborious, time consuming method. To achieve faster analysis, with increased throughput, a (downscaled) luminescent derivative of the Ames Salmonella/microsome fluctuation test has been developed through expression of the Photorhabdus luminescens luciferase in the Salmonella TA98 and TA100 strains. The applicability of this test is demonstrated by analysis of environmentally relevant compounds, a suspended particulate matter extract and an industrial effluent sample. Use of the luminescent reporter reduced the required detection time from 48 to 28 h with a specificity of 84% for responses reported in the literature to a set of 14 mutagens as compared to 72% in the unmodified fluctuation test. Testing of the same compounds in a downscaled luminescent format resulted in an 88% similarity with the response found in the regular luminescent format. The increase in throughput, faster analysis and potential for real-time bacterial quantification that luminescence provides, allows future application in the high-throughput screening of large numbers of samples or sample fractions, as required in effect-directed analysis in order to accelerate the identification of (novel) mutagens.

KW - Ames test

KW - Bacterial luciferase

KW - Bioassay

KW - Downscaling

KW - Mutagenicity testing

KW - Salmonella

UR - http://www.scopus.com/inward/record.url?scp=85030639393&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85030639393&partnerID=8YFLogxK

U2 - 10.1016/j.tiv.2017.09.005

DO - 10.1016/j.tiv.2017.09.005

M3 - Article

VL - 46

SP - 350

EP - 360

JO - Toxicology in Vitro

T2 - Toxicology in Vitro

JF - Toxicology in Vitro

SN - 0887-2333

ER -