Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures

  • Leon D. Gruenewald
  • , Vitali Koch
  • , Simon S. Martin
  • , Ibrahim Yel
  • , Katrin Eichler
  • , Tatjana Gruber-Rouh
  • , Lukas Lenga
  • , Julian L. Wichmann
  • , Leona S. Alizadeh
  • , Moritz H. Albrecht
  • , Christoph Mader
  • , Nicole A. Huizinga
  • , Tommaso D’Angelo
  • , Silvio Mazziotti
  • , Stefan Wesarg
  • , Thomas J. Vogl
  • , Christian Booz*
  • *Corresponding author for this work

Research output: Contribution to Journal › Article › Academic › peer-review

Abstract

Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p <.001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p <.001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. Key Points: •Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).

Original languageEnglish
Pages (from-to)3076-3084
Number of pages9
JournalEuropean Radiology
Volume32
Issue number5
Early online date9 Sept 2021
DOIs
Publication statusPublished - May 2022

Bibliographical note

Publisher Copyright:
© 2021, The Author(s).

Keywords

  • Bone density
  • Bone diseases, Metabolic
  • CT dual-energy computed tomography
  • Osteoporosis
  • Osteoporotic fractures