Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment

R. van der Togt, E.J. van Lieshout, R.A. Hensbroek, E. Beinat, J.M. Binnekade, P.J.M. Bakker

Research output: Contribution to JournalArticleAcademicpeer-review

Abstract

Context: Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never been reported. Objective: To assess and classify incidents of EMI by RFID on critical care equipment. Design and Setting: Without a patient being connected, EMI by 2 RFID systems (active 125 kHz and passive 868 MHz) was assessed under controlled conditions during May 2006, in the proximity of 41 medical devices (in 17 categories, 22 different manufacturers) at the Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands. Assessment took place according to an international test protocol. Incidents of EMI were classified according to a critical care adverse events scale as hazardous, significant, or light. Results: In 123 EMI tests (3 per medical device), RFID induced 34 EMI incidents: 22 were classified as hazardous, 2 as significant, and 10 as light. The passive 868-MHz RFID signal induced a higher number of incidents (26 incidents in 41 EMI tests; 63%) compared with the active 125-kHz RFID signal (8 incidents in 41 EMI tests; 20%); difference 44% (95% confidence interval, 27%-53%; P<.001). The passive 868-MHz RFID signal induced EMI in 26 medical devices, including 8 that were also affected by the active 125-kHz RFID signal (26 in 41 devices; 63%). The median distance between the RFID reader and the medical device in all EMI incidents was 30 cm (range, 0.1-600 cm). Conclusions: In a controlled nonclinical setting, RFID induced potentially hazardous incidents in medical devices. Implementation of RFID in the critical care environment should require on-site EMI tests and updates of international standards. ©2008 American Medical Association. All rights reserved.
Original languageEnglish
Pages (from-to)2884-2890
Number of pages7
JournalJAMA
Volume299
Issue number24
DOIs
Publication statusPublished - 2008

Fingerprint

Dive into the research topics of 'Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment'. Together they form a unique fingerprint.

Cite this