Evaluation of methods to assess push/pull forces in a construction task

M J Hoozemans, Allard J. Van Der Beek, M H Frings-Dresena, Henk F. Van der Molen

    Research output: Contribution to JournalArticleAcademicpeer-review

    Abstract

    The objective of the present study was to determine the validity of methods to assess push/pull forces exerted in a construction task. Forces assessed using a hand-held digital force gauge were compared to those obtained using a highly accurate measuring frame. No significant differences were found between the methods, except for peak push forces, for which the forces assessed with the force gauge were significantly lower than those assessed with the measuring frame. When the construction task was reproduced close to the actual workplace by simulation against a fixed object using the force gauge, all exerted forces on the force gauge were significantly lower than those on the measuring frame, except for mean pull forces. When self-reports were compared to the exerted forces on the measuring frame, the construction workers overestimated the exerted push/pull forces by 50%. In conclusion, when applied for direct measurements, the force gauge can be used to validly assess push/pull forces at the workplace.

    Original languageEnglish
    Pages (from-to)509-16
    Number of pages8
    JournalApplied Ergonomics
    Volume32
    Issue number5
    DOIs
    Publication statusPublished - Oct 2001

    Fingerprint

    Workplace
    Gages
    workplace
    evaluation
    Self Report
    Hand
    worker
    simulation

    Keywords

    • Adult
    • Anthropometry
    • Humans
    • Isometric Contraction
    • Male
    • Muscle, Skeletal
    • Occupational Health
    • Posture
    • Reproducibility of Results
    • Task Performance and Analysis
    • Journal Article
    • Research Support, Non-U.S. Gov't

    Cite this

    Hoozemans, M J ; Van Der Beek, Allard J. ; Frings-Dresena, M H ; Van der Molen, Henk F. / Evaluation of methods to assess push/pull forces in a construction task. In: Applied Ergonomics. 2001 ; Vol. 32, No. 5. pp. 509-16.
    @article{d38a898f36154c3b905d7d681739d27d,
    title = "Evaluation of methods to assess push/pull forces in a construction task",
    abstract = "The objective of the present study was to determine the validity of methods to assess push/pull forces exerted in a construction task. Forces assessed using a hand-held digital force gauge were compared to those obtained using a highly accurate measuring frame. No significant differences were found between the methods, except for peak push forces, for which the forces assessed with the force gauge were significantly lower than those assessed with the measuring frame. When the construction task was reproduced close to the actual workplace by simulation against a fixed object using the force gauge, all exerted forces on the force gauge were significantly lower than those on the measuring frame, except for mean pull forces. When self-reports were compared to the exerted forces on the measuring frame, the construction workers overestimated the exerted push/pull forces by 50{\%}. In conclusion, when applied for direct measurements, the force gauge can be used to validly assess push/pull forces at the workplace.",
    keywords = "Adult, Anthropometry, Humans, Isometric Contraction, Male, Muscle, Skeletal, Occupational Health, Posture, Reproducibility of Results, Task Performance and Analysis, Journal Article, Research Support, Non-U.S. Gov't",
    author = "Hoozemans, {M J} and {Van Der Beek}, {Allard J.} and Frings-Dresena, {M H} and {Van der Molen}, {Henk F.}",
    year = "2001",
    month = "10",
    doi = "10.1016/S0003-6870(01)00021-7",
    language = "English",
    volume = "32",
    pages = "509--16",
    journal = "Applied Ergonomics",
    issn = "0003-6870",
    publisher = "Elsevier Limited",
    number = "5",

    }

    Hoozemans, MJ, Van Der Beek, AJ, Frings-Dresena, MH & Van der Molen, HF 2001, 'Evaluation of methods to assess push/pull forces in a construction task' Applied Ergonomics, vol. 32, no. 5, pp. 509-16. https://doi.org/10.1016/S0003-6870(01)00021-7

    Evaluation of methods to assess push/pull forces in a construction task. / Hoozemans, M J; Van Der Beek, Allard J.; Frings-Dresena, M H; Van der Molen, Henk F.

    In: Applied Ergonomics, Vol. 32, No. 5, 10.2001, p. 509-16.

    Research output: Contribution to JournalArticleAcademicpeer-review

    TY - JOUR

    T1 - Evaluation of methods to assess push/pull forces in a construction task

    AU - Hoozemans, M J

    AU - Van Der Beek, Allard J.

    AU - Frings-Dresena, M H

    AU - Van der Molen, Henk F.

    PY - 2001/10

    Y1 - 2001/10

    N2 - The objective of the present study was to determine the validity of methods to assess push/pull forces exerted in a construction task. Forces assessed using a hand-held digital force gauge were compared to those obtained using a highly accurate measuring frame. No significant differences were found between the methods, except for peak push forces, for which the forces assessed with the force gauge were significantly lower than those assessed with the measuring frame. When the construction task was reproduced close to the actual workplace by simulation against a fixed object using the force gauge, all exerted forces on the force gauge were significantly lower than those on the measuring frame, except for mean pull forces. When self-reports were compared to the exerted forces on the measuring frame, the construction workers overestimated the exerted push/pull forces by 50%. In conclusion, when applied for direct measurements, the force gauge can be used to validly assess push/pull forces at the workplace.

    AB - The objective of the present study was to determine the validity of methods to assess push/pull forces exerted in a construction task. Forces assessed using a hand-held digital force gauge were compared to those obtained using a highly accurate measuring frame. No significant differences were found between the methods, except for peak push forces, for which the forces assessed with the force gauge were significantly lower than those assessed with the measuring frame. When the construction task was reproduced close to the actual workplace by simulation against a fixed object using the force gauge, all exerted forces on the force gauge were significantly lower than those on the measuring frame, except for mean pull forces. When self-reports were compared to the exerted forces on the measuring frame, the construction workers overestimated the exerted push/pull forces by 50%. In conclusion, when applied for direct measurements, the force gauge can be used to validly assess push/pull forces at the workplace.

    KW - Adult

    KW - Anthropometry

    KW - Humans

    KW - Isometric Contraction

    KW - Male

    KW - Muscle, Skeletal

    KW - Occupational Health

    KW - Posture

    KW - Reproducibility of Results

    KW - Task Performance and Analysis

    KW - Journal Article

    KW - Research Support, Non-U.S. Gov't

    U2 - 10.1016/S0003-6870(01)00021-7

    DO - 10.1016/S0003-6870(01)00021-7

    M3 - Article

    VL - 32

    SP - 509

    EP - 516

    JO - Applied Ergonomics

    JF - Applied Ergonomics

    SN - 0003-6870

    IS - 5

    ER -