Heat flux systems are increasingly used to assess core body temperature. However, validation of multiple systems is scarce. Therefore, an experiment was performed in which three commercially available heat flux systems (3 M, Medisim and Core) were compared to rectal temperature (Tre). Five females and four males performed exercise in a climate chamber set at 18 °C/50% relative humidity until exhaustion. Exercise duration was 36.3 ± 5.6 min (mean ± standard deviation). Tre in rest was 37.2 ± 0.3 °C. Medisim's-values were lower than Tre (36.9 ± 0.4 °C, p < 0.05); 3 M (37.2 ± 0.1 °C) and Core's (37.4 ± 0.3 °C) did not differ from Tre. Maximal temperatures after exercise were 38.4 ± 0.2 °C (Tre), 38.0 ± 0.4 °C (3 M), 38.8 ± 0.3 °C (Medisim) and 38.6 ± 0.3 °C (Core); Medisim was significantly higher than Tre (p < 0.05). The temperature profiles of the heat flux systems during exercise differed to varying degree from the rectal profiles; the Medisim system showed a faster increase during exercise than Tre (0.48 ± 0.25 °C in 20 min, p < 0.05), the Core system tended to show a systematic overestimation during the entire exercise period and the 3 M system showed large errors at the end of exercise, likely due to sweat entering the sensor. Therefore, the interpretation of heat flux sensor values as core body temperature estimates should be done with care; more research is required to elucidate the physiological significance of the generated temperature values.
| Original language | English |
|---|---|
| Article number | 103480 |
| Pages (from-to) | 1-6 |
| Number of pages | 6 |
| Journal | Journal of Thermal Biology |
| Volume | 112 |
| Early online date | 14 Jan 2023 |
| DOIs | |
| Publication status | Published - Feb 2023 |
Bibliographical note
Funding Information:Surgical Company is acknowledged for providing financial support for the study. This company had no involvement in study design, in the collection, analysis and interpretation of data and in the writing of the report. The company approved the decision to submit the article for publication.
Funding Information:
Surgical Company is acknowledged for providing financial support for the study. This company had no involvement in study design, in the collection, analysis and interpretation of data and in the writing of the report. The company approved the decision to submit the article for publication.
Publisher Copyright:
© 2023
Funding
Surgical Company is acknowledged for providing financial support for the study. This company had no involvement in study design, in the collection, analysis and interpretation of data and in the writing of the report. The company approved the decision to submit the article for publication. Surgical Company is acknowledged for providing financial support for the study. This company had no involvement in study design, in the collection, analysis and interpretation of data and in the writing of the report. The company approved the decision to submit the article for publication.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Accuracy
- Rectal temperature
- Skin temperature
- Thermometry
Fingerprint
Dive into the research topics of 'Heat flux systems for body core temperature assessment during exercise'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver