T1 - Is outdoor use of the six-minute walk test with a global positioning system in stroke patients' own neighbourhoods reproducible and valid?
AU - Wevers, L.E.
AU - Kwakkel, G.
AU - van de Port, I.G.
PY - 2011
Y1 - 2011
N2 - Objective: To examine the reproducibility, responsiveness and concurrent validity of the six-minute walk test (6MWT) when tested outdoors in patients' own neighbourhoods using a global positioning system (GPS) or a measuring wheel. Methods: A total of 27 chronic stroke patients, discharged to their own homes, were tested twice, within 5 consecutive days. The 6MWT was conducted using a GPS and an measuring wheel simultaneously to determine walking distance. Reproducibility was determined as test-retest reliability and agreement, using the intraclass correlation coefficient, standard error of measurement and Bland & Altman plots. Responsiveness was expressed as the smallest real difference and visualized in Bland & Altman plots. Pearson's correlation coefficient (r) was used to study concurrent validity between the GPS and measuring wheel. Results: Intraclass correlation coefficiens were 0.96 for the GPS and 0.98 for the measuring wheel, and standard error of measurement scores were 11.9 m for the measuring wheel and 18.1 m for the GPS, resulting in smallest real differences of 33.0 m and 50.2 m, respectively. Concurrent validity was strong (r = 0.99). Conclusion: These results indicate that the outdoor 6MWT using a GPS or measuring wheel is reproducible, responsive and concurrently valid. This suggests that therapists working in the community can use the outdoor 6MWT as a reliable, responsive and valid test. © 2011 Foundation of Rehabilitation Information.
AB - Objective: To examine the reproducibility, responsiveness and concurrent validity of the six-minute walk test (6MWT) when tested outdoors in patients' own neighbourhoods using a global positioning system (GPS) or a measuring wheel. Methods: A total of 27 chronic stroke patients, discharged to their own homes, were tested twice, within 5 consecutive days. The 6MWT was conducted using a GPS and an measuring wheel simultaneously to determine walking distance. Reproducibility was determined as test-retest reliability and agreement, using the intraclass correlation coefficient, standard error of measurement and Bland & Altman plots. Responsiveness was expressed as the smallest real difference and visualized in Bland & Altman plots. Pearson's correlation coefficient (r) was used to study concurrent validity between the GPS and measuring wheel. Results: Intraclass correlation coefficiens were 0.96 for the GPS and 0.98 for the measuring wheel, and standard error of measurement scores were 11.9 m for the measuring wheel and 18.1 m for the GPS, resulting in smallest real differences of 33.0 m and 50.2 m, respectively. Concurrent validity was strong (r = 0.99). Conclusion: These results indicate that the outdoor 6MWT using a GPS or measuring wheel is reproducible, responsive and concurrently valid. This suggests that therapists working in the community can use the outdoor 6MWT as a reliable, responsive and valid test. © 2011 Foundation of Rehabilitation Information.
U2 - 10.2340/16501977-0881
DO - 10.2340/16501977-0881
M3 - Article
SN - 1650-1977
VL - 43
SP - 1027
EP - 1031
JO - Journal of Rehabilitation Medicine
JF - Journal of Rehabilitation Medicine
IS - 11
ER -