Online screening of homogeneous catalyst performance using reaction detection mass spectrometry

C.T. Martha, N. Elders, J.G. Krabbe, J. Kool, W.M.A. Niessen, R.V.A. Orru, H. Irth

Research output: Contribution to JournalArticleAcademicpeer-review

Abstract

An integrated online screening system was developed to rapidly screen homogeneous catalysts for activity toward a selected synthesis. The continuous-flow system comprises standard HPLC pumps for the delivery of substrates, an HPLC autosampler for the injection of homogeneous catalysts, a thermostated reactor to mediate synthesis, and a single-stage quadrupole mass spectrometer (MS) equipped with atmospheric pressure chemical ionization for the determination of product formation. MS detection offers sensitivity, specificity, and speed when applied to the analysis of dynamic processes in the condensed phase. By applying the present methodology for the study of substrate conversion mediated by homogeneous catalysts, the concentration of substrates and reaction product could be monitored while information about the catalysts could also be obtained. In an initial screening application, the performance of a selected number of Lewis acids in the multicomponent synthesis of a highly substituted 2-imidazoline was determined. Limit of detection and limit of quantitation were determined by injecting different concentrations of 2-imidazoline standards and proved to be 1.6 and 5.2 nM, respectively. The results obtained with the new screening method were in good agreement with a traditional bench-scale experiment. Moreover, the system was capable of determining catalyst performance with very low catalyst and solvent consumption while the ruggedness of the system was exhibited with a 24-h continuous analysis of 280 successive catalyst injections with a peak area variation within 7% relative standard deviation. © 2008 American Chemical Society.
Original languageEnglish
Pages (from-to)7121-7
JournalAnalytical Chemistry
Volume80
Issue number18
DOIs
Publication statusPublished - 2008

Fingerprint

Mass spectrometry
Screening
Catalysts
Mass spectrometers
Substrates
Lewis Acids
Reaction products
Atmospheric pressure
Ionization
Pumps
Experiments

Cite this

@article{a0d14a88c9ca4c03879da6a48fd63652,
title = "Online screening of homogeneous catalyst performance using reaction detection mass spectrometry",
abstract = "An integrated online screening system was developed to rapidly screen homogeneous catalysts for activity toward a selected synthesis. The continuous-flow system comprises standard HPLC pumps for the delivery of substrates, an HPLC autosampler for the injection of homogeneous catalysts, a thermostated reactor to mediate synthesis, and a single-stage quadrupole mass spectrometer (MS) equipped with atmospheric pressure chemical ionization for the determination of product formation. MS detection offers sensitivity, specificity, and speed when applied to the analysis of dynamic processes in the condensed phase. By applying the present methodology for the study of substrate conversion mediated by homogeneous catalysts, the concentration of substrates and reaction product could be monitored while information about the catalysts could also be obtained. In an initial screening application, the performance of a selected number of Lewis acids in the multicomponent synthesis of a highly substituted 2-imidazoline was determined. Limit of detection and limit of quantitation were determined by injecting different concentrations of 2-imidazoline standards and proved to be 1.6 and 5.2 nM, respectively. The results obtained with the new screening method were in good agreement with a traditional bench-scale experiment. Moreover, the system was capable of determining catalyst performance with very low catalyst and solvent consumption while the ruggedness of the system was exhibited with a 24-h continuous analysis of 280 successive catalyst injections with a peak area variation within 7{\%} relative standard deviation. {\circledC} 2008 American Chemical Society.",
author = "C.T. Martha and N. Elders and J.G. Krabbe and J. Kool and W.M.A. Niessen and R.V.A. Orru and H. Irth",
year = "2008",
doi = "10.1021/ac801003h",
language = "English",
volume = "80",
pages = "7121--7",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "18",

}

Online screening of homogeneous catalyst performance using reaction detection mass spectrometry. / Martha, C.T.; Elders, N.; Krabbe, J.G.; Kool, J.; Niessen, W.M.A.; Orru, R.V.A.; Irth, H.

In: Analytical Chemistry, Vol. 80, No. 18, 2008, p. 7121-7.

Research output: Contribution to JournalArticleAcademicpeer-review

TY - JOUR

T1 - Online screening of homogeneous catalyst performance using reaction detection mass spectrometry

AU - Martha, C.T.

AU - Elders, N.

AU - Krabbe, J.G.

AU - Kool, J.

AU - Niessen, W.M.A.

AU - Orru, R.V.A.

AU - Irth, H.

PY - 2008

Y1 - 2008

N2 - An integrated online screening system was developed to rapidly screen homogeneous catalysts for activity toward a selected synthesis. The continuous-flow system comprises standard HPLC pumps for the delivery of substrates, an HPLC autosampler for the injection of homogeneous catalysts, a thermostated reactor to mediate synthesis, and a single-stage quadrupole mass spectrometer (MS) equipped with atmospheric pressure chemical ionization for the determination of product formation. MS detection offers sensitivity, specificity, and speed when applied to the analysis of dynamic processes in the condensed phase. By applying the present methodology for the study of substrate conversion mediated by homogeneous catalysts, the concentration of substrates and reaction product could be monitored while information about the catalysts could also be obtained. In an initial screening application, the performance of a selected number of Lewis acids in the multicomponent synthesis of a highly substituted 2-imidazoline was determined. Limit of detection and limit of quantitation were determined by injecting different concentrations of 2-imidazoline standards and proved to be 1.6 and 5.2 nM, respectively. The results obtained with the new screening method were in good agreement with a traditional bench-scale experiment. Moreover, the system was capable of determining catalyst performance with very low catalyst and solvent consumption while the ruggedness of the system was exhibited with a 24-h continuous analysis of 280 successive catalyst injections with a peak area variation within 7% relative standard deviation. © 2008 American Chemical Society.

AB - An integrated online screening system was developed to rapidly screen homogeneous catalysts for activity toward a selected synthesis. The continuous-flow system comprises standard HPLC pumps for the delivery of substrates, an HPLC autosampler for the injection of homogeneous catalysts, a thermostated reactor to mediate synthesis, and a single-stage quadrupole mass spectrometer (MS) equipped with atmospheric pressure chemical ionization for the determination of product formation. MS detection offers sensitivity, specificity, and speed when applied to the analysis of dynamic processes in the condensed phase. By applying the present methodology for the study of substrate conversion mediated by homogeneous catalysts, the concentration of substrates and reaction product could be monitored while information about the catalysts could also be obtained. In an initial screening application, the performance of a selected number of Lewis acids in the multicomponent synthesis of a highly substituted 2-imidazoline was determined. Limit of detection and limit of quantitation were determined by injecting different concentrations of 2-imidazoline standards and proved to be 1.6 and 5.2 nM, respectively. The results obtained with the new screening method were in good agreement with a traditional bench-scale experiment. Moreover, the system was capable of determining catalyst performance with very low catalyst and solvent consumption while the ruggedness of the system was exhibited with a 24-h continuous analysis of 280 successive catalyst injections with a peak area variation within 7% relative standard deviation. © 2008 American Chemical Society.

U2 - 10.1021/ac801003h

DO - 10.1021/ac801003h

M3 - Article

VL - 80

SP - 7121

EP - 7127

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 18

ER -