Skip to main navigation Skip to search Skip to main content

Optical properties of advanced lithium disilicate

Research output: Contribution to JournalArticleAcademicpeer-review

Abstract

BACKGROUND: A variety of firing protocols are available for the IPS e.max lithium disilicate (LD) and can be used for new, 'advanced' LD (ALD). However, the impact of firing protocols on the optical properties of ALD is still unknown.

OBJECTIVES: The aim of the present study was to evaluate the color difference (ΔE00), the translucency parameter (TP00) and the whiteness index for dentistry (WID) for both LD glass ceramics after the processes of firing/glazing.

MATERIAL AND METHODS: Fifty disk-shaped specimens, with a diameter of 10 mm and a thickness of 1.2 mm, were fabricated from IPS e.max CAD (LD; Ivoclar) and another 50 from CEREC Tessera™ (ALD; Dentsply Sirona). The specimens from each group were further divided into 5 subgroups (n = 10) according to the firing/glazing protocol applied: crystallization (c); one-step crystallization and glazing (cg); crystallization and refiring (c-r); two-step crystallization and glazing (c-g); or long-firing crystallization (lfc). The ΔE00, TP00 and WID were assessed. The statistical analysis of ΔE00 was performed using the one-way analysis of variance (ANOVA) and Tukey's post hoc test, while TP00 and WID were analyzed with the two-way ANOVA and Tukey's post hoc test at a statistical significance level of 0.05. The cg groups were designated as the reference.

RESULTS: The ANOVA showed that the firing procedures had no effect on ΔE00, TP00 and WID in the case of LD. In addition, LD exhibited greater translucency and brightness as compared to ALD. For ALD, all color changes observed in relation to the reference firing protocol were clinically unacceptable. The ALD specimens which underwent 1 standard firing cycle showed higher TP00 and WID values than other ALD groups.

CONCLUSIONS: The choice of the firing protocol has no impact on the color, TP00 or WID of LD. Additionally, LD presents higher WID values than ALD, irrespective of the firing protocol used. Alternative firing protocols result in clinically unacceptable color variations when compared to the manufacturer-recommended protocol for ALD. Advanced LD is more sensitive to different firing protocols with regard to its optical properties, which makes the workflow less predictable in comparison with LD.

Original languageEnglish
Pages (from-to)691-699
Number of pages9
JournalDental and Medical Problems
Volume62
Issue number4
Early online date26 Sept 2024
DOIs
Publication statusPublished - Aug 2025

Funding

The research was supported by the Brazilian Federal Agency for the Coordination of Improvement of Higher Education Personnel (CAPES) (finance code 001 – doctoral scholarship of Lucas Saldanha da Rosa).

Funders
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

    Keywords

    • CAD/CAM
    • dental materials
    • glass ceramics
    • optical properties

    Fingerprint

    Dive into the research topics of 'Optical properties of advanced lithium disilicate'. Together they form a unique fingerprint.

    Cite this