Skip to main navigation Skip to search Skip to main content

Outcome in patient-specific PEEK cranioplasty: a two-center cohort study of 40 implants

  • J. Jonkergouw
  • , S.E.C.M. van de Vijfeijken
  • , E. Nout
  • , T. Theys
  • , E. Van de Casteele
  • , H. Folkersma
  • , P.R.A.M. Depauw
  • , A.G. Becking

Research output: Contribution to JournalArticleAcademicpeer-review

Abstract

Objective: The best material choice for cranioplasty following craniectomy remains a subject to discussion. Complication rates after cranioplasty tend to be high. Computer-assisted 3-dimensional modelling of polyetheretherketone (PEEK) was recently introduced for cranial reconstruction. The aim of this study was to evaluate patient- and surgery-related characteristics and risk factors that predispose patients to cranioplasty complications.
Material and methods: This retrospective study included a total of 40 cranial PEEK implants in 38 patients, performed at two reference centers in the Netherlands from 2011 to 2014. Complications were registered and patient- and surgery-related data were carefully analysed.
Results: The overall complication rate of PEEK cranioplasty was 28%. Complications included infection (13 %), postoperative haematoma (10 %), cerebrospinal fluid leak (2.5 %) and wound-related problems (2.5 %). All postoperative infections required removal of the implant. Nonetheless removed implants could be successfully re-used after re-sterilization.
Conclusion: Although overall complication rates after PEEK cranioplasty remain high, outcomes are satisfactory, as our results compare favourably to recent literature reports on cranial vault reconstruction.
Original languageEnglish
Pages (from-to)1266-1272
JournalJournal of Cranio-Maxillofacial Surgery
Volume44
Issue number9
DOIs
Publication statusPublished - 2016