Pitfalls and practical suggestions for using local field potential recordings in DBS clinical practice and research

  • Bart E K S Swinnen
  • , Arthur W G Buijink
  • , Mariëlle J Stam
  • , Deborah Hubers
  • , Martijn de Neeling
  • , Bart J Keulen
  • , Francesca Morgante
  • , Bernadette C M van Wijk
  • , Rob M A de Bie
  • , Lucia Ricciardi
  • , Simon J Little
  • , Martijn Beudel

Research output: Contribution to JournalArticleAcademicpeer-review

Abstract

Objective. Local field potential (LFP) recordings using chronically implanted sensing-enabled stimulators are a powerful tool for indexing symptom presence and severity in neurological and neuropsychiatric disorders, and for enhancing our neurophysiological understanding of brain processes. LFPs have gained interest as input signals for closed-loop deep brain stimulation (DBS) and can be used to inform DBS parameter selection. LFP recordings using chronically implanted sensing-enabled stimulators have various implementational challenges. Approach. Here we describe our collective experience using BrainSense (Medtronic®) for clinical and research work. We aim to provide insightful tips and practical advice to empower readers with the knowledge needed to navigate the intricacies of the device and make the most out of its features. Main results. The central issues that apply to several BrainSense features encompass restricted compatibility of stimulation configuration with sensing, differences in electrophysiological signal properties between ‘stimulation OFF’ and ‘stimulation ON at 0.0 mA’, and challenges associated with the internal clock of the neurostimulator. In addition, since recordings are obtained from bipolar and not monopolar channels, spatial certainty regarding the distribution of LFPs around the DBS electrode is limited. Several options exist to synchronize LFP time series with external data streams, but standardization and generalization are lacking. The use of at-home chronic LFP recording is limited by a low temporal and spectral resolution. Regarding at-home LFP snapshots, LFP time series are not stored, parts of the power spectrum are censored when stimulating at high or low frequencies, and the stimulation amplitude is not readily available. Significance. We discussed practical applications, implementation, system limitations, and pitfalls with the aim that sensing can be better applied for clinical practice and research.
Original languageEnglish
Article number014001
JournalJournal of Neural Engineering
Volume22
Issue number1
DOIs
Publication statusPublished - 1 Feb 2025

Funding

FundersFunder number
Medical Research CouncilMR/T023864/1

    Fingerprint

    Dive into the research topics of 'Pitfalls and practical suggestions for using local field potential recordings in DBS clinical practice and research'. Together they form a unique fingerprint.

    Cite this