Abstract
This study investigated the shear bond strength (SBS) of various cements to zirconia ceramic. CoCr-cylinders were bonded to zirconia plates (20 mm × 10 mm × 2 mm; n = 8 per group) using four self-adhesive resin cements (one capsule, three hand-mixed) and four resin cements, partly in combination with a tribochemical/silane treatment. All cements were auto-polymerizing. The bonding areas were sandblasted using 110 μm Al2O3. The shear bond strength was determined after 24 h, 30 days, 90 days of water storage (37°C) and after 12 000 thermal cycles. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Bonferroni post hoc test (α = 0.05).
After 24 h and after thermal cycling (TC) the lowest value of shear bond strength was found for the control Variolink without bonding pre-treatment (9.5 MPa/3.1 MPa) and the highest results were determined for Calibra with bonding pre-treatment (37.3 MPa/31.9 MPa). After 30 days and 90 days of storage in water the highest SBS values were found for RelyX (33.3 MPa/28.6 MPa), and again lowest values were determined for Variolink (8.8 MPa/9.1 MPa). After 90 days storage all samples of Maxcem failed. The groupwise comparison revealed significantly different SBS results between 90 days storage and the initial results after 24 h (p = 0.003). No significant differences were found between the other storage conditions (p > 0.057). The systems without bonding pre-treatment provided significantly lower SBS in comparison to the self-adhesive systems and the systems with bonding pre-treatment (p = 0.000).
Within the limitations of this study, three of four self-adhesive bonding systems provided bond strengths to zirconia, comparable to systems with additional bonding pre-treatment. The durability of the bonding resin and zirconia can only be judged after long-term water storage.
After 24 h and after thermal cycling (TC) the lowest value of shear bond strength was found for the control Variolink without bonding pre-treatment (9.5 MPa/3.1 MPa) and the highest results were determined for Calibra with bonding pre-treatment (37.3 MPa/31.9 MPa). After 30 days and 90 days of storage in water the highest SBS values were found for RelyX (33.3 MPa/28.6 MPa), and again lowest values were determined for Variolink (8.8 MPa/9.1 MPa). After 90 days storage all samples of Maxcem failed. The groupwise comparison revealed significantly different SBS results between 90 days storage and the initial results after 24 h (p = 0.003). No significant differences were found between the other storage conditions (p > 0.057). The systems without bonding pre-treatment provided significantly lower SBS in comparison to the self-adhesive systems and the systems with bonding pre-treatment (p = 0.000).
Within the limitations of this study, three of four self-adhesive bonding systems provided bond strengths to zirconia, comparable to systems with additional bonding pre-treatment. The durability of the bonding resin and zirconia can only be judged after long-term water storage.
| Original language | English |
|---|---|
| Pages (from-to) | 1125-1132 |
| Number of pages | 8 |
| Journal | Journal of Adhesion Science and Technology |
| Volume | 23 |
| Issue number | 7-8 |
| DOIs | |
| Publication status | Published - 2009 |
Bibliographical note
Published online: 02 April 2012UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Fingerprint
Dive into the research topics of 'Shear bond strength of cement to zirconia'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver