Abstract
The BaBaR Silicon Vertex Tracker (SVT) has been efficiently operated for five years since the start of data taking in 1999. It has met design requirements and no degradation in its performance has been observed thus far. However, because of higher than expected background levels, and anticipated further increases in luminosity and dose rates, we have done a thorough study to assess the viability of operating the SVT until the end of the decade. © 2005 Elsevier B.V. All rights reserved.
| Original language | English |
|---|---|
| Pages (from-to) | 5-8 |
| Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| Volume | 560 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 1 May 2006 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Status and prospects of the BaBar SVT'. Together they form a unique fingerprint.Cite this