Abstract
Aim To compare the ability of cone-beam computed tomography (CBCT) and digital periapical radiographs (PR) to detect simulated tissue-occupied recesses in root canals.
Methodology A standard canal was created in 30 extracted mandibular premolar roots. Each root was longitudinally split into buccal and lingual halves. In 20 teeth, a standard groove, 4 mm in length, 0.5 mm deep and 0.3 mm wide, was prepared on each root half and filled with radiolucent plasticine (a modelling clay), simulating tissue-occupied buccal and lingual recesses. In the other 10 teeth, no grooves were cut. Each root was reassembled and filled with laterally compacted gutta-percha and sealer. PR and CBCT were used to detect the plasticine-filled grooves. The images were pooled and blindly evaluated by three calibrated examiners (A, B and C). A chi-square test was used to analyse the data.
Results Examiner A, B, C detected grooves on CBCT scans in 20, 20 and 23 teeth, respectively, of which 19, 18 and 19 were true positives. The accuracy of CBCT in diagnosing plasticine-filled grooves was 82-92% for three examiners, significantly higher than the accuracy of PR (30-33%; P < 0.001).
Conclusions Cone-beam computed tomography accurately detected simulated tissue-occupied buccal and lingual recesses.
Methodology A standard canal was created in 30 extracted mandibular premolar roots. Each root was longitudinally split into buccal and lingual halves. In 20 teeth, a standard groove, 4 mm in length, 0.5 mm deep and 0.3 mm wide, was prepared on each root half and filled with radiolucent plasticine (a modelling clay), simulating tissue-occupied buccal and lingual recesses. In the other 10 teeth, no grooves were cut. Each root was reassembled and filled with laterally compacted gutta-percha and sealer. PR and CBCT were used to detect the plasticine-filled grooves. The images were pooled and blindly evaluated by three calibrated examiners (A, B and C). A chi-square test was used to analyse the data.
Results Examiner A, B, C detected grooves on CBCT scans in 20, 20 and 23 teeth, respectively, of which 19, 18 and 19 were true positives. The accuracy of CBCT in diagnosing plasticine-filled grooves was 82-92% for three examiners, significantly higher than the accuracy of PR (30-33%; P < 0.001).
Conclusions Cone-beam computed tomography accurately detected simulated tissue-occupied buccal and lingual recesses.
| Original language | English |
|---|---|
| Pages (from-to) | 724-729 |
| Journal | International Endodontic Journal |
| Volume | 45 |
| Issue number | 8 |
| DOIs | |
| Publication status | Published - 2012 |
Fingerprint
Dive into the research topics of 'The ability of cone-beam computed tomography to detect simulated buccal and lingual recesses in root canals'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver