The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis

T. Flügge, W.J. van der Meer, B.G. Gonzalez, K. Vach, D. Wismeijer, P. Wang

Research output: Contribution to JournalReview articleAcademicpeer-review

Abstract

Aim: This systematic review and meta-analysis were conducted to assess and compare the accuracy of conventional and digital implant impressions. The review was registered on the PROSPERO register (registration number: CRD42016050730).
Material and Methods: A systematic literature search was conducted adhering to PRISMA guidelines to identify studies on implant impressions published between 2012 and 2017. Experimental and clinical studies at all levels of evidence published in peer-reviewed journals were included, excluding expert opinions. Data extraction was performed along defined parameters for studied specimens, digital and conventional impression specifications and outcome assessment. Results: Seventy-nine studies were included for the systematic review, thereof 77 experimental studies, one RCT and one retrospective study. The study setting was in vitro for most of the included studies (75 studies) and in vivo for four studies. Accuracy of conventional impressions was examined in 59 studies, whereas digital impressions were examined in 11 studies. Nine studies compared the accuracy of conventional and digital implant impressions. Reported measurements for the accuracy include the following: (a) linear and angular deviations between reference models and test models fabricated with each impression technique; (b) three-dimensional deviations between impression posts and scan bodies respectively; and (c) fit of implant-supported frameworks, assessed by measuring marginal discrepancy along implant abutments.) Meta-analysis was performed of 62 studies. The results of conventional and digital implant impressions exhibited high values for heterogeneity.
Conclusions: The available data for accuracy of digital and conventional implant impressions have a low evidence level and do not include sufficient data on in vivo application to derive clinical recommendations.
Original languageEnglish
Pages (from-to)374-392
JournalClinical Oral Implants Research
Volume29
Issue numberS16
DOIs
Publication statusPublished - 2018

Bibliographical note

In special issue: Proceedings of the Sixth ITI Consensus Conference.

Fingerprint

Dive into the research topics of 'The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis'. Together they form a unique fingerprint.

Cite this