The diagnostic accuracy of headache measurement instruments: A Systematic Review and Meta-Analysis focusing on Headaches associated with Musculoskeletal Symptoms

Hedwig A van der Meer, Corine M Visscher, Tom Vredeveld, Maria Wg Nijhuis van der Sanden, Raoul Engelbert, Caroline M Speksnijder

Research output: Contribution to JournalReview articleAcademicpeer-review

Abstract

AIM: To systematically review the available literature on the diagnostic accuracy of questionnaires and measurement instruments for headaches associated with musculoskeletal symptoms.DESIGN: Articles were eligible for inclusion when the diagnostic accuracy (sensitivity/specificity) was established for measurement instruments for headaches associated with musculoskeletal symptoms in an adult population. The databases searched were PubMed (1966-2018), Cochrane (1898-2018) and Cinahl (1988-2018). Methodological quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist for criterion validity. When possible, a meta-analysis was performed. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) recommendations were applied to establish the level of evidence per measurement instrument.RESULTS: From 3450 articles identified, 31 articles were included in this review. Eleven measurement instruments for migraine were identified, of which the ID-Migraine is recommended with a moderate level of evidence and a pooled sensitivity of 0.87 (95% CI: 0.85-0.89) and specificity of 0.75 (95% CI: 0.72-0.78). Six measurement instruments examined both migraine and tension-type headache and only the Headache Screening Questionnaire - Dutch version has a moderate level of evidence with a sensitivity of 0.69 (95% CI 0.55-0.80) and specificity of 0.90 (95% CI 0.77-0.96) for migraine, and a sensitivity of 0.36 (95% CI 0.21-0.54) and specificity of 0.86 (95% CI 0.74-0.92) for tension-type headache. For cervicogenic headache, only the cervical flexion rotation test was identified and had a very low level of evidence with a pooled sensitivity of 0.83 (95% CI 0.72-0.94) and specificity of 0.82 (95% CI 0.73-0.91).DISCUSSION: The current review is the first to establish an overview of the diagnostic accuracy of measurement instruments for headaches associated with musculoskeletal factors. However, as most measurement instruments were validated in one study, pooling was not always possible. Risk of bias was a serious problem for most studies, decreasing the level of evidence. More research is needed to enhance the level of evidence for existing measurement instruments for multiple headaches.
Original languageEnglish
Pages (from-to)1313-1332
Number of pages20
JournalCephalalgia
Volume39
Issue number10
Early online date18 Apr 2019
DOIs
Publication statusPublished - Sept 2019

Funding

This study was funded by the Dutch Organisation for Scientific Research (Nederlandse Organisatie voor Wetenschappelijk Onderzoek – NWO) [grant number 023.006.004]. There is no conflict of interest within this study. This study was funded by the Dutch Organisation for Scientific Research (Nederlandse Organisatie voor Wetenschappelijk Onderzoek ? NWO) [grant number 023.006.004]. There is no conflict of interest within this study. The authors disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The Dutch Organisation for Scientific Research (Nederlandse Organisatie voor Wetenschappelijk Onderzoek – NWO) [grant number 023.006.004].

FundersFunder number
Dutch Organisation for Scientific Research
Nederlandse Organisatie voor Wetenschappelijk Onderzoek023.006.004
Aard- en Levenswetenschappen, Nederlandse Organisatie voor Wetenschappelijk Onderzoek

    Fingerprint

    Dive into the research topics of 'The diagnostic accuracy of headache measurement instruments: A Systematic Review and Meta-Analysis focusing on Headaches associated with Musculoskeletal Symptoms'. Together they form a unique fingerprint.

    Cite this